Gasoline only. One required per engine. Up to 3 engines supported.
-
Outputs:
- Fuel Flow
- Tank Fuel Used
- Trip Fuel Used
- Seasonal Fuel Used
Cable Length: 10 Ft
Fuel Line Diameter: 3/8" (9.5 mm) Inside Diameter
Flow Rate Measured: Optimized for 0.6-45 Gal/hr but can measure outside these values
Added Back Pressure to the fuel system: 0.5 PSI at 20 Gal/hr; 1 PSI at 40 Gal/hr
Installation Location: Above the max level of the fuel tank, in-line after the fuel filter and any Y's or T's in the line
Package: The EP-60R, LowranceNet T and 2 (two) 1" hose clamps
Fuel Type: Gasoline only. The EP-60R does not operate diesel engine fuel systems, or on any fuel system with a return fuel line or sump.
Hole required to route through a bulkhead: 7/8" (22mm)
Multiple EP-60R sensors possible: Yes
For use with LowranceNET networks with red connectors (do not connect to blue connectors).