To find a stockist in your region, click here
Yokogawa CMZ900B Gyrocompass

|
Settling Time
and Accuracy |
Settling time
|
Within 5 hours
(Operational state is reached in about 2 hours) |
|
|
Accuracy
|
Static: ±0.25 deg.x sec (Latitude)
Dynamic: ±0.75 deg.x sec (Latitude) |
||
|
Follow up accuracy
|
0.1 deg. or less
|
||
|
Max. follow up speed
|
30 deg./s
|
||
|
Environmental
(Normal use) |
Permissible angle
|
±40 deg.(Roll), ±40 deg. (Pitch)
|
|
|
Ambient temperature
|
-10 deg.C to +55 deg.C
|
||
|
Power Supply
|
Main
|
24V DC
AC adapter (Option), type MKR027 is available on 100V/110V/115V/220V AC 50/60Hz single-phase |
|
|
Alarm
|
24 V DC
|
||
|
Signal Inputs
|
External heading
|
IEC61162-1 (NMEA0183)
|
1 circuit
|
|
Options (Available on adding C.Operation unit, type MKR024)
|
|||
|
Automatic
speed error correction |
Optional
|
||
|
Latitude
|
IEC61162-1 (NMEA0183)
|
1 circuit
|
|
|
Ship's speed
|
200 P/nm or IEC61162-1 (NMEA0183)
|
1 circuit
|
|
|
External heading
(For deviation alarm) |
IEC61162-1 (NMEA0183)
(Supplied to C.Operation unit, MKR024) |
1 circuit
|
|
|
Signal Outputs
|
Heading data for repeater compasses
|
3 circuits
|
|
|
Heading data for steppers
|
1 circuit
|
||
|
Serial data
|
IEC61162-1
|
1 circuit
|
|
|
IEC61162-1/-2 selective
|
2 circuits
|
||
|
Gyro. running (Close contact when running)
|
1 circuit
|
||
|
Alarms (Open contact
when abnormal) |
System failure
|
1 circuit
|
|
|
No voltage
|
1 circuit
|
||
Manufacturers Webpage: www.yokogawa.com/ydk/mr/marine/gyro/index.htm